替代241Am低能光子源的准单色X射线机的研制

Manufacture Quasi-monochromatic X-ray Machine to Replace 241Am Low Energy Photon Source

  • 摘要: 研究了用滤光片法产生50~60 keV的准单色X射线的条件,对输出的X射线进行了数种金属滤光片实验研究,选出合适的滤光片,通过实验对准直器的机械结构进行了确定。采用自行设计委托加工的X射线管、准直器和购买的高压电源,组装成符合实验要求的X射机。该装置输出了50~60 keV能量段的准单色光谱,在料位计上能替代241Am低能光子源。

     

    Abstract: A practical approach to produce 50-60 keV quasi-monochromatic X-ray by selection metal filter was studied. The appropriate metal filter was selected after various types of filters were tested. The mechanical structure of the collimator was also determined. According to the experimental requirement, a X-ray machine was assembled with a X-ray tube, a collimator and an ultrahigh voltage power source. This device generates standard spectrum of quasi-monochromatic X-ray in the energy range of 50-60 keV, and the X-ray machine can present an appropriate substitution to 241Am low energy photon source in the traditional level indicator.

     

/