  • 摘要: 核电厂高压给水加热器系统的应急疏水阀用于加热器的水位控制。本文根据某核电厂的经验反馈,对CPR100机组应急疏水阀的控制逻辑进行优化。试验结果表明,优化后的控制方案实施效果良好,高压给水加热器水位在瞬态过程中的较大扰动下能迅速稳定。

     

    Abstract: The high level control valve of the high pressure feedwater heater system in nuclear power plant is used to control the water level of the feedwater heater. According to experience from some nuclear power plant, the control logic of the high level control valve for CPR1000 was improved. The test results show that the water level of the high pressure feedwater heater can return to stable level quickly after upset condition during the transient test.

     

/