Abstract:
The RELAP5/MOD3.3 code was adopted to compute the SBO accident condition of a swimming pool reactor. The coolant flow reversal process was calculated, and the influence of parameters of the flow between the core leakage and components on the flow reversal in the SBO accident condition was analyzed. The calculated results show that in the situation the reactor loses all forced flow, the residual heat of the reactor can be removed by the natural circulation flow, and the fuel subassembly will not be damaged.