CEFR一回路冷阱更换过程中的钠钾合金灌装

NaK Filling Technology in Cold Trap Replacement Process of CEFR Primary Loop

  • 摘要: 介绍了中国实验快堆(CEFR)一回路2#冷阱更换过程中的钠钾合金灌装方案,灌装回路的设计、建造及调试,灌装过程安全防护措施和废钠钾合金的处理,并向CEFR备用冷阱内灌装447.4 kg钠钾合金,对废钠钾合金进行处理。结果表明,所采用的钠钾合金灌装方法、钠钾合金回路活接头冷冻拆卸技术、钠管道切割除钠技术、废钠钾合金处理方法安全可靠,人员安全防护措施得当。本文方法也可用于指导CEFR一回路1#冷阱的更换。

     

    Abstract: The 2# cold trap replacement scheme in the primary loop of China Experimental Fast Reactor (CEFR) was introduced, including the design, construct and commissioning of the filling loop, the protective methods for safety in the filling procedure and the disposal of NaK waste. Filling of 447.4 kg NaK into the backup cold trap of CEFR and disposal of the waste NaK were completed successfully and safely. The results show that the method of filling NaK, the freezing and disassembling technique of the NaK loop connector, the cutting and sodium removing technology for the sodium pipes and the treatment for NaK waste are reliable and safe. Additionally, the protective measures for the safety of operators are suitable. Moreover, the technology introduced in the paper is applicable for the replacement of the 1# cold trap in the primary loop of CEFR.

     

/