CYCIAE-100紧凑型回旋加速器低温板排气系统理论和实验研究
Theory and Experiment Research of Cryopanel Exhaust System Used in CYCIAE-100 Compact Cyclotron
-
摘要: 根据CYCIAE-100紧凑型回旋加速器的结构特点,设计了一套大抽速低温板排气系统,插入到CYCIAE-100紧凑型回旋加速器主磁铁谷区中,该套排气系统将使CYCIAE-100紧凑型回旋加速器加速腔内真空度好于5×10-6 Pa。目前该套低温板排气系统已设计完成,用Monte-Carlo方法对其进行了优化,并进行了加工、安装和初步调试,调试时低温冷板上温度达19 K,CYCIAE-100紧凑型回旋加速器加速腔内真空度达到8×10-6 Pa。
-
关键词:
- CYCIAE-100紧凑型回旋加速器 ,
- 真空 ,
- 低温冷却系统 ,
- 大抽速 ,
- 插入式低温板排气系统 ,
- Monte-Carlo模拟计算
Abstract: A set of large pumping speed tailored cryopanel exhaust system placed in CYCIAE-100 compact cyclotron magnet valley area was designed for high vacuum requirement, which makes pressure in the main tank better than 5×10-6 Pa. The Monte-Carlo method was used to optimize the designed structure based on the characteristics of magnet valley area. The machining and commission of cryopanel exhaust system has been done. After the first commission, the temperature on cryopanel reaches 19 K, and the pressure in CYCIAE-100 compact cyclotron main tank reaches 8×10-6 Pa. -
-
[1] 张天爵,李振国,储诚节,等. 用于放射性核束设施驱动加速器的100 MeV强流质子回旋加速器[J]. 高能物理与核物理,2006,30(2):159-161.ZHANG Tianjue, LI Zhenguo, CHU Chengjie, et al. 100 MeV high intensity proton cyclotron as a driving accelerator for the radioactive ion beam facility[J]. High Energy Physics and Nuclear Physics, 2006, 30(2): 159-161(in Chinese). [2] 李振国. 100 MeV真空系统初步设计[R]. 北京:中国原子能科学研究院,2007. [3] 高香院. 现代低温泵[M]. 西安:西安交通大学出版社,1992. [4] KUSH G. International symposium on “vacuum science and technology”[C]. India: [s. n.], 2007. [5] 杨乃恒. 真空获得设备[M]. 北京:冶金工业出版社,1987:56-60. [6] 达道安. 真空设计手册[M]. 北京:国防工业出版社,2004:416-420. [7] 潘高峰,张素平,李振国. HI-13串列加速器升级工程CYCIAE-100回旋加速器主真空系统设计报告[R]. 北京:中国原子能科学研究院,2009. [8] 张素平,潘高峰,张天爵,等. CYCIAE-100回旋加速器低温冷板参数的蒙特卡罗模拟[J]. 原子能科学技术,待发表.ZHANG Suping, PAN Gaofeng, ZHANG Tianjue, et al. Monte-Carlo simulation of cryopanel parameter in CYCIAE-100 cyclotron[J]. Atomic Energy Science and Technology, in press(in Chinese). [9] 彭楠,熊联友,张亮,等. 低温真空泵辐射挡板流导几率的计算[J]. 低温工程,2006,154(6):21-24.PANG Nan, XIONG Lianyou, ZHANG Liang, et al. Calculation of transmission probability of cryopump radiation baffle[J]. Cryogenics, 2006, 154(6): 21-24(in Chinese). [10] 张素平,张天爵,潘高峰,等. 插入式低温冷板模拟抽气系统设计和实验[J]. 真空与低温,2015,21(3):177-180. ZHANG Suping, ZHANG Tianjue, PAN Gaofeng, et al. The design and test of plug-in cryopanel simulated pumping system[J]. Vacuum & Cryogenics, 2015, 21(3): 177-180(in Chinese). [11] 潘高峰,张素平,张天爵,等. 实验低温冷板抽气装置性能测试及分析[J]. 真空,2015,52(3):1-4. PAN Gaofeng, ZHANG Suping, ZHANG Tianjue, et al. Performance test and analysis of experimental cryopanel pumping system[J]. Vacuum, 2015, 52(3): 1-4(in Chinese).
计量
- 文章访问数: 394
- HTML全文浏览量: 0
- PDF下载量: 1067