  • 摘要: 对采用国产新锆合金的压水堆燃料实验小组件(4×3)进行了压降计算,并将计算结果与堆外水力试验结果进行对比,得到了该小组件的水力特性参数。通过对定位格架正面凸出截面积与自由流通截面积之比ε的适当修正,得到了合理的定位格架阻力系数。分析结果表明:在升温(28.0~310.0 ℃)过程中,定位格架阻力系数取值范围为0.660~1.060;在高压、高温(15.3 MPa,309.9 ℃)工况下其取值为0.663;4组定位格架形阻压降占模拟燃料组件压降的38.9%~45.6%。

     

    Abstract: The pressure drop calculation of domestic new zirconium alloy fuel assembly (4×3) for pressurized water reactor was conducted. The calculation result was compared with hydraulic test’s result and the hydraulic characteristic parameters of fuel assembly were acquired. Reasonable pressure loss coefficient of grid spacer was obtained by the revision of the ratio of cross-section area of the grid spacer in the flow path to the unobstructed coolant flow area. The analysis results show that the pressure loss coefficient of grid spacer ranges from 0.660 to 1.060 under heating condition (28.0-310.0 ℃) and equals to 0.663 under high pressure and high temperature (15.3 MPa, 309.9 ℃) conditions. The pressure drop due to the four grid spacers occupies 38.9%-45.6% of the total pressure loss of the simulation fuel assembly.

     

/