  • 摘要: HLS-Ⅱ恒温冷却水控制系统用于控制冷却水的温度变化,减少外部环境对设备的影响,以提高光源运行的稳定性。该系统是基于EPICS设计的分布式控制系统,采用串口以太网转换器MOXA6450将数字指示调节器UT55A-20接入到控制局域网中,温度控制在UT55A-20中实现,IOC运行在VMWare虚拟机上。系统自2015年以来运行稳定可靠,冷却水温度控制精度达到了±0.5 ℃的设计指标,为HLS-Ⅱ的稳定供光提供了必要的技术支持。

     

    Abstract: The constant temperature cooling water control system of HLS-Ⅱ is used to control the cooling water temperature change, and reduces the effect of the external environment on the equipment to improve the stability of the light source operation. The system is a distributed control system based on EPICS, and uses a serial port Ethernet converter MOXA6450 to connect digital indicating controller UT55A-20 to the LAN. The temperature control is implemented in UT55A-20, and IOC runs on VMWare virtual machine. The system has been stable and reliable since 2015, and the control precision of cooling water temperature reaches ±0.5 ℃ design indicators. The system provides the necessary technical support for the stable supply light of HLS-Ⅱ.

     

/