Analysis of Seismic Fragility Parameter of Fluid-filled Container

  • 摘要: 本文介绍了核电厂设备的易损性分析方法以及易损性模型的参数化计算方法。对核电厂中的典型储液容器应急补水箱(ASG水箱)使用Housner质量-弹簧简化模型进行了分析。对ASG水箱的各项易损性参数进行了计算,绘制出其易损性曲线,并得出高置信度低失效概率(HCLPF)值。结果表明:ASG水箱的HCLPF值低于安全停堆地震(SSE)水平,属于抗震能力较低的设备,需在结构上进行加强。

     

    Abstract: The seismic fragility analysis method of the equipment in nuclear power plant and the parameterized seismic fragility analysis model were introduced in this paper. The Housner model was adopted to calculate the dynamical response of a typical fluid-filled container (ASG tank) in nuclear power plant. The median value, variability and uncertainty of each seismic fragility parameter of ASG tank were calculated. The fragility curve was drawn, and the value of high confidence of low probability of failure (HCLPF) was obtained. The results show that the ASG tank has a lower HCLPF value than the safe shutdown earthquake (SSE) level and is the equipment with low seismic resistance. It needs to be structurally strengthened.

     

/