固态热管反应堆模拟装置热工水力特性分析

Analysis of Thermal-hydraulic Characteristic of Solid Heat Pipe Reactor Simulator Device

  • 摘要: 热管反应堆具有小型化、结构简单、固有安全性高等优势,有着广泛的应用前景和研究意义。本文采用CFD方法对热管反应堆模拟装置进行了稳态工况下的热工水力特性分析,并与实验结果进行对比。结果表明,热管各测点温度相对误差不超过5.5%,温差发电器热端各测点温度相对误差不超过3.1%,证明了该模型方法的可行性和正确性。本研究为热管反应堆的数值模拟提供理论指导与方法支撑。

     

    Abstract: Heat pipe reactor has the advantages of small size, simple structure and high inherent safety, which has a wide application prospect and research significance. In this paper, CFD method was used to analyze the thermal-hydraulic characteristics of a heat pipe reactor simulator device under steady state conditions, and the results were compared with the experimental results. The results show that the relative temperature error of each measuring point of the heat pipe is less than 5.5%, and the relative temperature error of each measuring point at the hot end of the thermoelectric generator is less than 3.1%. This study provides theoretical guidance and method support for numerical simulation of heat pipe reactor.

     

/

返回文章
返回