热离子能量转换器中电极有效功函数的间接测量方法

Indirect Measurement Method for Effective Work Function of Electrode in Thermionic Energy Converter

  • 摘要: 常规的功函数测试方法很难直接测出高温Cs环境下的电极材料的功函数,已有的计算吸Cs功函数的经验公式对新型电极材料的适用性尚未得到验证,且测量吸Cs功函数时电极并非处于发电状态下的电弧工况,因此亟需建立相关的实验方法对电极材料服役环境下的有效功函数进行评价。基于热离子能量转换中电极间电子流的能量平衡方程,结合热电转换过程中近电极区域的独立电特性,分别建立了发射极和接收极的有效功函数的间接测量方法。应用此方法获得了W发射极和Ni接收极在特定运行工况下的有效功函数,将其与文献中材料的吸Cs功函数进行比较分析。结果表明,W发射极和Ni接收极的有效功函数与文献报道的吸Cs功函数的平均相对误差分别为5.74%和3.86%,且电极有效功函数的间接测量结果与热离子能量转换的发电特性自洽相符,这是此前吸Cs功函数相关的测量结果所不能体现的。

     

    Abstract: In the thermionic energy conversion of Cs-charged, the work function of the electrodes, especially the effective work function of the electrode material in the Cs-absorbing state, has a decisive impact on its power generation performance. However, it is difficult to measure the work function in the high-temperature Cs environment for the test method at this stage, so establishing relevant experimental methods to evaluate the work function of the electrode material in the real environment is necessary. Based on the energy balance equation of electron flow between electrodes in thermionic energy conversion, combined with the local characteristics of electrode influence in the thermoelectric conversion process, the indirect measurement method of the effective work function of the emitter and collector was established by processing the current-volt characteristic curves under specific operating parameters. Furthermore, the data processing program was compiled by Matlab language, then the effective work function of the electrode material at different temperatures could be directly output. A series of current-volt characteristic data were obtained by using the current-volt characteristic program in the literature, and the current-volt characteristic data of Ni with only changing the temperature of the collector were tested by using a self-built plate-electrode experimental device. The parameters such as current density, voltage and electrode temperature in the current-volt characteristic results were substituted into the effective work function calculation model. The effective work functions of W emitter and Ni collector under different power generation currents under specific operating conditions subsequently were calculated separately, compared with the test values of the Cs-absorbing work function tested in the literature, which not measured under arc conditions during power generation. The results show that the effective work function of the emitter is approximately positively correlated with the Rasor index, decreasing with the increase of current density, which is caused by the Schottky effect. The changes of the effective work function of the collector with the working condition are consistent with the change trend of the influence of the collector temperature on the output power. Furthermore, there is an optimal collector temperature, in the vicinity of which the effective work function is the lowest. The average relative errors of the effective work functions of the emitter and collector and the literature values of the Cs-absorbing work function are 5.74% and 3.86%, respectively. The indirect measurement results of the effective work function can be consistent with the power generation characteristics of the thermionic energy conversion, which could be reflected in the previous test results of the Cs-absorbing work function.

     

/

返回文章
返回