COSINE软件中气泡和液滴模型及参数的不确定性量化研究

Quantitative Study on Uncertainty of Bubble and Droplet Models and Parameters in COSINE Code

  • 摘要: 为提高COSINE多相场代码用于最佳估算大破口失水事故的准确性和鲁棒性,本文基于热工分离实验和水力台架试验,采用该代码进行了建模和数值计算。并通过两种灵敏度量化分析方法,给出并分析了温度、水装量等数据的计算误差。此外,对影响参数进行了定量分析,并对参数之间的交互作用进行了讨论。结果表明:下降段水装量结果的计算带很宽,再淹没结果的计算带范围很窄;液滴直径限制对下降段水装量影响起主要作用,气相和液滴摩擦系数对再淹没阶段包壳最高温度影响最为显著。此外,参数模型的交互作用广泛存在,液滴和气泡直径限制对数值计算的影响明显;液滴相间摩擦对其与壁面间换热有显著影响。

     

    Abstract: Large break loss of coolant accident is the most severe design basis accident. To study the uncertainty of droplet and bubble behavior models, an evaluation was conducted on the independent software COSINE multiphase field subchannel code to calculate the results of large break loss of coolant accidents. In response to the mechanism of large break loss of coolant accidents, its specialized software serves as an analysis tool, which puts higher demands on the accuracy and suitability of key process law analysis models. The above indicators depend on the depth of the model’s understanding and mechanism analysis of important physical processes. In order to improve the accuracy and robustness of COSINE multiphase field code for optimal estimation of large break loss of coolant accidents, the code was used for modeling and numerical calculations based on thermal hydraulic experiments in this paper. And two sensitivity quantification analysis methods were used to provide and analyze the calculation bias of temperature and water inventory. In addition, quantitative analysis was conducted on the influencing parameters and the interaction between the parameters was discussed. The results show that the calculation band for the water inventory results in the downcorner section of the refilling stage is very wide, with a maximum relative error of 33.15%, the interphase interaction between vapor and liquid has a significant impact on the mass flow rate. The calculation range of the maximum temperature of the cladding results during the reflooding stage is very narrow, and the relative error of the peak temperature of the cladding is within 3.5%, the uncertainty error of calculation is continuously amplified on the time scale. The limitation of droplet diameter plays a major role in the influence of water inventory in the downcorner section, with a correlation coefficient of 0.27. As the dimensionless velocity of the upward steam formed in the descending section changes, the diameter of the droplet directly affects its interfacial area, resulting in changes in interphase heat transfer and friction. The friction coefficients of gas and liquid droplets have the most significant impact on the maximum temperature of the cladding during the reflooding stage, with a correlation coefficient of 0.54. The relative velocity of gas and droplets determines the enhancement factor of gas convection in dispersed flow film boiling, and shows a positive correlation. In addition, the diameter limitations of droplets and bubbles have a significant impact on numerical calculations. The friction between liquid and droplets has a significant relationship with the heat transfer between droplets and the wall.

     

/

返回文章
返回