WANG Xing-hai, LI Shi-chang, CHEN Jing. Online Measurement Method for Pulse Amplitude in Pulsed Extraction Columns[J]. Atomic Energy Science and Technology, 2009, 43(2): 133-137. DOI: 10.7538/yzk.2009.43.02.0133
Citation: WANG Xing-hai, LI Shi-chang, CHEN Jing. Online Measurement Method for Pulse Amplitude in Pulsed Extraction Columns[J]. Atomic Energy Science and Technology, 2009, 43(2): 133-137. DOI: 10.7538/yzk.2009.43.02.0133

Online Measurement Method for Pulse Amplitude in Pulsed Extraction Columns

More Information
  • Received Date: December 31, 1899
  • Revised Date: December 17, 2007
  • Online measurement of pulse amplitude by air purge was studied. The pulse amplitude in a pulsed extraction column was calculated online by measurement of characteristic parameters of the signal’s curve. The method can be used for calculation of different pulsed extraction columns.
  • [1]
    姜圣阶,任凤仪. 核燃料后处理工学[M]. 北京:原子能出版社,1995:328.
    [2]
    陈靖,吴秋林,徐世平,等. 30%TRPO-煤油/硝酸体系在脉冲萃取柱中的水力学特性[J]. 清华大学学报:自然科学版,2000, 40(6):91-94.
    CHEN Jing, WU Qiulin, XU Shiping, et al. Hydrodynamic characteristics of 30% TRPO-kerosene/nitric acid solution in pulsed extraction column [J]. J Tsinghua University: Sci & Tech, 2000, 40(6): 91-94(in Chinese).
    [3]
    傅蓉. 脉冲萃取柱参数的在线测量与控制研究[D]. 北京:清华大学,2002.
    [4]
    陈靖,徐世平,吴秋林. 吹气法在线测量脉冲萃取柱参数研究[J]. 原子能科学技术,2001,35(增刊):34-40.
    CHEN Jing, XU Shiping, WU Qiulin. On-line measurement of pulsed column parameters by air purge [J]. At Energy Sci Technol, 2001, 35(Suppl.): 34-40(in Chinese).
    [5]
    王悦云. 折流板脉冲萃取柱性能研究[D]. 北京:清华大学,2005.
    [6]
    刘凯. 折流板脉冲萃取柱水力学性能研究[D]. 山东:烟台大学,2006.
    [7]
    李世昌. 折流板脉冲萃取柱脉冲振幅测量研究[D]. 山东:烟台大学,2007.
  • Related Articles

    [1]ZENG Xin, LI Shao-wei, JING Shan, LIU Ji-lian, WU Qiu-lin. Effect of Air Capacity and Air Resistance on Measurement of Instantaneous Pressure Drop of Column Weight in Pulsed Extraction Column[J]. Atomic Energy Science and Technology, 2015, 49(6): 997-1004. DOI: 10.7538/yzk.2015.49.06.0997
    [2]LI Shao-wei, ZENG Xin, JING Shan, LIU Ji-lian, WU Qiu-lin. Effect of Tube Length on Measurement of Instantaneous Pressure Drop of Column Weight in Pulsed Extraction Column[J]. Atomic Energy Science and Technology, 2014, 48(3): 395-400. DOI: 10.7538/yzk.2014.48.03.0395
    [3]WANG Yue-yun, LI Shao-wei, JING Shan. Pressure Drop Measurement of Column Weight in Disc and Doughnut Pulsed Extraction Column by External Air Purge Method[J]. Atomic Energy Science and Technology, 2013, 47(12): 2182-2185. DOI: 10.7538/yzk.2013.47.12.2182
    [4]WANG Shu-wei, JING Shan, WU Qiu-lin. New Auto-control Principle of Phase Interface for Pulsed Extraction Column[J]. Atomic Energy Science and Technology, 2008, 42(11): 1001-1006. DOI: 10.7538/yzk.2008.42.11.1001
    [5]JING Shan, WU Qiu-lin. Design Method of Air Tube in Bottom Settler of Pulsed Extraction Column for Air Purge Method[J]. Atomic Energy Science and Technology, 2008, 42(7): 602-605. DOI: 10.7538/yzk.2008.42.07.0602
    [6]JING Shan, WU Qiu-lin. Effect of Air Pulsation on Pressure Measurement in Bottom Settler of Pulsed Extraction Column by Air Purge Method[J]. Atomic Energy Science and Technology, 2008, 42(5): 408-415. DOI: 10.7538/yzk.2008.42.05.0408
    [7]JING Shan, WU Qiu-lin, WANG Yue-yun. On-Line Measurement of Pulsed Amplitude for Standard Spray-Sieve-Plates Pulsed Extraction Column[J]. Atomic Energy Science and Technology, 2008, 42(4): 292-295. DOI: 10.7538/yzk.2008.42.04.0292
    [8]JING Shan, WANG Yue-yun, WU Qiu-lin. On-Line Determination of Pulsed Parameters for Pulsed Extraction[J]. Atomic Energy Science and Technology, 2007, 41(6): 716-721. DOI: 10.7538/yzk.2007.41.06.0716
    [9]JING Shan, WU Qiu-lin, WANG Yue-yun, CHEN Jing. Effect of Air Purge on Measurement of Pulsed Amplitude for Pulsed Extraction Column[J]. Atomic Energy Science and Technology, 2007, 41(5): 537-539. DOI: 10.7538/yzk.2007.41.05.0537
    [10]CHEN Jing, XU Shi ping, WU Qiu lin, LIU Bing ren, TAI De rong, SONG Chong li(Institute of Nuclear Energy Technology, Tsinghua University, Beijing 102201, China). On-line Measurement of Pulsed Column Parameters by Air Purge[J]. Atomic Energy Science and Technology, 2001, 35(S1): 34-34. DOI: 10.7538/yzk.2001.35.S1.0034

Catalog

    Article views (914) PDF downloads (1320) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return