ZHANG Wei-hua, WANG Zhi-qiang, YU Wei-xiang. Construction of Tissue-Equivalent Proportional Counter System[J]. Atomic Energy Science and Technology, 2010, 44(11): 1379-1384. DOI: 10.7538/yzk.2010.44.11.1379
Citation: ZHANG Wei-hua, WANG Zhi-qiang, YU Wei-xiang. Construction of Tissue-Equivalent Proportional Counter System[J]. Atomic Energy Science and Technology, 2010, 44(11): 1379-1384. DOI: 10.7538/yzk.2010.44.11.1379

Construction of Tissue-Equivalent Proportional Counter System

More Information
  • Received Date: December 31, 1899
  • Revised Date: December 31, 1899
  • The principles and methods of tissue-equivalent proportional counter (TEPC) system were investigated. A set of measuring system based on TEPC was constructed, which was used to measure the absorbed dose and the dose equivalent in the neutron, gamma mixed field. There are always photons existing in the neutron field, so the micro-dosimetric spectra of mixed fields always include the two parts from photons and neutrons respectively. And the two parts can be simply separated according to their shapes. The micro-dosimetric spectra were obtained from the pulse height spectra, and the neutron and gamma components were analyzed. The simulation calculation was performed by Monte-Carlo method, whose result is in agreement with the measured data. Then, we know that the measurement of TEPC system is practicable.
  • [1]
    田志恒. 辐射剂量学[M]. 北京:原子能出版社,1992.
    [2]
    ATTIX F H. Introduction to radiological physics and radiation dosimetry, WILEYVCH[M]. [S.l.] : [s.n.], 2004.
    [3]
    WAKER A J. Principles of experimental microdosimetry[J]. Radiation Protection Dosimetry, 1995, 61(4): 297-308.
    [4]
    ROSSI H H, FAILLA G. Tissue equivalent ionization chambers[J]. Nu- Cleonics, 1956, 14: 32.
    [5]
    SRDOC D. Experimental technique of measurement of microscopic energy distribution in irradiated matter using Rossi counte[J]. Radiat Res, 1970, 43: 302.
    [6]
    DIETZE G, MENZEL H G, BUHLER G. Calibration of tissue-equivalent proportional counters used as radiation protection dosemeters[J]. Radiation Protection Dosimetry, 1984, 9(3): 245-249.
    [7]
    ANTHONY J W. Experimental uncertainties in microdosimetric measurements and an examination of the performance of three commerially produced proportional counters[J]. Nuclear Instruments and Methods in Physics Research A, 1985, 234: 354-360.
    [8]
    The quality factor in radiation protection, ICRU report 40[R]. Bethesda, Maryland: International Commission on Radiation Units and Measurements, 1986.
    [9]
    SCHREWE U J, BREDE H J, DIETZE G. Dosimetry in mixed neutron-photon fields with tissueevuivalent proportional counters[J]. Radiation Protection Dosimetry, 1989, 29(1/2): 41-45.
  • Related Articles

    [1]HUANG Jin-feng, WANG Ying, XIONG Wen-jun, LUO Zhi-ping, CHEN Ling. Study on Simple G(E) Function Calculation Method of CdZnTe Detector Based on Monte-Carlo Method and Peak Shape Fitting[J]. Atomic Energy Science and Technology, 2017, 51(1): 165-169. DOI: 10.7538/yzk.2017.51.01.0165
    [2]SHANGGUAN Dan-hua, LI Gang, DENG Li, ZHANG Bao-yin. Design of Tallying Function for General Purpose Monte Carlo Particle Transport Code JMCT[J]. Atomic Energy Science and Technology, 2013, 47(增刊2): 640-644. DOI: 10.7538/yzk.2013.47.S1.0640
    [3]WU Jian, LEI Jia-rong, LIU Wen-ke. Monte-Carlo Simulation of Intensity of Tritium Lamp[J]. Atomic Energy Science and Technology, 2013, 47(3): 481-484. DOI: 10.7538/yzk.2013.47.03.0481
    [4]HUA Zheng-dong. Monte-Carlo Simulation of Conversion Coefficient for Air Kerma From Photon Fluence[J]. Atomic Energy Science and Technology, 2010, 44(6): 647-649. DOI: 10.7538/yzk.2010.44.06.0647
    [5]ZHANG Li-guo, SHANG Ren-cheng. Performance Analysis of Collimator in Online Burnup Measurement System for Pebble Modular HighTemperature GasCooled Reactor With MonteCarlo Method[J]. Atomic Energy Science and Technology, 2009, 43(9): 1-807. DOI: 10.7538/yzk.2009.43.09.0813
    [6]SUN Liang, LI Jun-li, BAO Yong-di, JI Xiao-dong. Determination of Dose Calculation Parameters for Model CS-1 131Cs Brachytherapy Source With Monte-Carlo Method[J]. Atomic Energy Science and Technology, 2008, 42(8): 706-710. DOI: 10.7538/yzk.2008.42.08.0706
    [7]GENG Jin-peng, MA Yun-zhi, CAO Tian-guang, LI Yu-xiao, ZHUO Yi-zhong. Monte-Carlo Simulation of Cellular S Value and Specific Energy for Electrons[J]. Atomic Energy Science and Technology, 2007, 41(1): 14-19. DOI: 10.7538/yzk.2007.41.01.0014
    [8]LIU Jian-chang, SUN Ji-ing, YANG Xiao-yuan, GUO Bin, YE Wei-guo, HUANG Fei-zeng, Yang Yuan-di, HU Jian-cheng, FAN Tie-shuang. Monte-Carlo Calculation and Measurement of Wall Correction Factor for Spherical Graphite Ionization Chamber[J]. Atomic Energy Science and Technology, 2006, 40(6): 723-728. DOI: 10.7538/yzk.2006.40.06.0723
    [9]ZHANG Quan-hu, SUI Hong-zhi, LU Feng, LI Ze(China Institute of Atomic Energy, P.O.Box 275-48, Beijing 102413, China). Monte-Carlo Statistical Iteration Image Reconstruction Algorithm[J]. Atomic Energy Science and Technology, 2003, 37(6): 555-555. DOI: 10.7538/yzk.2003.37.06.0555
    [10]MONTE-CARLO CALCULATION OF NEUTRON PENETRATION SPECTRUM AND EXPERLMENTAL CHECK[J]. Atomic Energy Science and Technology, 1994, 28(2): 165-168. DOI: 10.7538/yzk.1994.28.02.0165

Catalog

    Article views (756) PDF downloads (1059) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return