GUO WENQI China Institute of Atomic Energy, P. O. Box 275, Beijing. THE DESIGN OF CONTROL ALGORITHM FOR AUTOMATIC START-UP MODEL OF HWRR[J]. Atomic Energy Science and Technology, 1990, 24(6): 73-73. DOI: 10.7538/yzk.1990.24.06.0073
Citation: GUO WENQI China Institute of Atomic Energy, P. O. Box 275, Beijing. THE DESIGN OF CONTROL ALGORITHM FOR AUTOMATIC START-UP MODEL OF HWRR[J]. Atomic Energy Science and Technology, 1990, 24(6): 73-73. DOI: 10.7538/yzk.1990.24.06.0073

THE DESIGN OF CONTROL ALGORITHM FOR AUTOMATIC START-UP MODEL OF HWRR

More Information
  • Received Date: May 20, 1990
  • The report describes the design of control algorithm for automatic start-upmodel of HWRR, the calculation of μ value and the application of digital com-pensator. Finally The flow diagram of the automatic start-up and digital com-pensator program for HWRR are given.
  • [1]
    Takumi, K. et al., IEEE, NS-15(1), 87(1968).
    [2]
    Takahashi, Y. et al., IEEE, NS-12(4), 355(1965).
    [3]
    Luopa, J. A. et al., IEEE, NS-17(1), 586(1970).
  • Related Articles

    [1]CAI Boshuai, YU Tianjun, LIN Xuan, ZHANG Jilong, WANG Zhixuan, YUAN Cenxi. Investigation of Nuclear Binding Energy and Charge Radius Based on Random Forest Algorithm[J]. Atomic Energy Science and Technology, 2023, 57(4): 704-712. DOI: 10.7538/yzk.2022.youxian.0780
    [2]JIN Xin, LI Dongyuan, QIN Ge, XU Jiaoshen, TANG Hui, WANG Xin. Design of LQG Controller for Nuclear Reactor Power Based on NSGA-Ⅱ Algorithm[J]. Atomic Energy Science and Technology, 2022, 56(10): 2085-2095. DOI: 10.7538/yzk.2021.youxian.0762
    [3]JIANG Liang-wei, LONG Feng-li, CHENG Jian. Digital Control of Power Factor Correction[J]. Atomic Energy Science and Technology, 2009, 43(7): 654-657. DOI: 10.7538/yzk.2009.43.07.0654
    [4]LI Feng-yu, ZHANG Da-fa, WANG Shao-ming, CUI Chang-ling, LIU Ying. PID Control for Nuclear Steam Generator Water Level Based on Genetic Algorithm[J]. Atomic Energy Science and Technology, 2008, 42(z1): 137-141. DOI: 10.7538/yzk.2008.42.z1.0137
    [5]ZHANG Fan, CHEN Wen-zhen, YU Lei. Correction Method for Critical Extrapolation of Control-Rods-Rising During Physical Start-Up of Reactor[J]. Atomic Energy Science and Technology, 2008, 42(4): 322-324. DOI: 10.7538/yzk.2008.42.04.0322
    [6]OU Huai-gu, LI Fu, ZHANG Liang-ju, FENG Jun-ting(Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China). A Digitalized Power Control System for Nuclear Reactor[J]. Atomic Energy Science and Technology, 2004, 38(S1): 1-1. DOI: 10.7538/yzk.2004.38.S1.0001
    [7]FENG Jun-ting, ZHANG Liang-ju, LI Duo(Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China). Digital Reactor Power Control System[J]. Atomic Energy Science and Technology, 2004, 38(6): 492-492. DOI: 10.7538/yzk.2004.38.06.0492
    [8]QU Rong-hong, LI Bao-xiang, XU Xiao-lin (Institute of Nuclear Energy Technology, Tsinghua University, Beijing 102201, China). Study and Application of Digital Physical Start-up System for Nuclear Reactor[J]. Atomic Energy Science and Technology, 2004, 38(2): 189-189. DOI: 10.7538/yzk.2004.38.02.0189
    [9]SHI Xiao ping, SAN Ye (Simulation Center, Harbin Institute of Technology, Harbin 150001, China). Self-tuning Model Algorithmic Control of Thermal Power Tracking System for the Nuclear Reactor[J]. Atomic Energy Science and Technology, 2002, 36(1): 67-67. DOI: 10.7538/yzk.2002.36.01.0067
    [10]SHI Xiao ping, XU Tian shu(Simulation Center, Harbin Institute of Technology, Harbin 150001,China). Simulation Study of Multi-step-Model Algorithmic Control of the Nuclear Reactor Thermal Power Tracking System[J]. Atomic Energy Science and Technology, 2001, 35(6): 525-525. DOI: 10.7538/yzk.2001.35.06.0525

Catalog

    Article views (861) PDF downloads (770) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return